Complete expertise, from measurement to continuous improvement

Whether you need a one-time diagnosis or permanent monitoring, Nettan Solutions supports you at every step to identify problems, recommend the best solutions, and ensure their long-term performance.

STEP 01

Power waveform quality audit and diagnosis

Measurement campaigns with high-precision analyzers — harmonics, voltage sags and swells, transients, imbalances, power factor, and overloads.

  • On-site visit and portable analyzer deployment
  • Waveform capture and power quality event recording
  • Investigation of both utility-side and internal causes
  • Written report with root cause findings
  • Technical and economic recommendations
Discuss this service
STEP 02

Advanced data analysis and recommendations

Identification of real causes from measured data. Complete report: trends, harmonic analysis, performance indicators, and prioritized recommendations.

  • Power consumption profile study
  • Harmonic distortion analysis (THD and individual harmonics)
  • Voltage quality review (sags, swells, interruptions)
  • Power factor and reactive power assessment
  • EN 50160 / IEC 61000-4-30 compliance check
  • Executive-ready report with prioritized action plan
Discuss this service
STEP 03

Continuous 24/7 monitoring

Permanent network monitoring — instant alarms, dashboards, automated reports, and complete event history, from the main meter down to individual loads. Intelligent analysis platforms with AI assistance.

  • Permanent or semi-permanent instrument installation
  • Real-time alerts to smartphone or email
  • Monthly power quality reports tailored to your team
  • Historical trend data retention
  • Remote supervision capability across all circuits
  • Detect anomalies before they reach the production floor
Discuss this service
STEP 04

Corrective solutions and continuous improvement

Supply, integration, and commissioning of corrective solutions — harmonic filters, capacitor banks, power factor correction, voltage stabilizers, UPS systems, and intelligent analysis platforms with AI assistance. Performance follow-up after commissioning.

  • Active and passive harmonic filters
  • Capacitor banks and power factor correction
  • Voltage stabilizers and UPS systems
  • Permanent monitoring systems and intelligent analysis platforms
  • On-site commissioning and integration
  • Performance follow-up after commissioning
Discuss this service

How a Nettan Engagement Works

Every engagement begins with measurement. From there, we follow the evidence.

01
Measure

Deploy instruments and capture the full electrical picture before drawing any conclusions.

02
Diagnose

Distinguish utility-side from internal causes. Identify patterns vs. isolated events.

03
Recommend

Technical findings paired with economic justification — clear priorities, not a parts list.

04
Implement

Corrective work coordinated with the right equipment and field partners.

05
Monitor

Continuous surveillance to catch what comes next — before it affects production.

A Partner-Ready Technical Advisor

Power quality problems rarely have a single stakeholder. Nettan can coordinate across utilities, manufacturers, engineers, and field teams.

Utilities

Nettan investigates whether disturbances originate upstream or downstream from the main meter — providing measured evidence that utilities and customers can act on together.

Equipment Manufacturers

OEMs developing mitigation products can collaborate with Nettan to accelerate problem resolution — covering First Article Testing, product interoperability, and system design.

Consulting Engineers / EPCs

Nettan can act as a technical advisor within larger projects — handling power audits, writing specifications, managing field start-ups, or integrating within an EPC-led project management structure.

Field Partners

Nettan works with trusted field partners for on-site surveillance setup, load fine-tuning, and 24/7 field services when continuous presence is required.

Power Quality Challenges We Solve

View All Applications →
Montreal High-Rise: Power Quality and Active Filters
Audit · Active Filters · 24/7 Monitoring

Montreal High-Rise: Power Quality and Active Filters

3 substations corrected. Harmonics reduced. Capacitor failures eliminated.
Pinpointing the Source: Utility-Side or Internal?
Diagnosis & Investigation

Pinpointing the Source: Utility-Side or Internal?

Root cause confirmed. Corrective plan agreed.
Keeping a Food Processing Plant Running — Continuously
Continuous Surveillance

Keeping a Food Processing Plant Running — Continuously

Reactive → preventive. Surprises eliminated.

Find Out What's Wrong With Your Electrical System

Our experts analyze your power quality data and deliver a detailed audit report.

Request a Power Audit